Field of application
The Deltapilot FMB53 is a cable version with mounting clamp. This device with the Contite measuring cell is typically used in the environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.
Inquiry Form
We will get in touch with you shortly
Description
Specification:
-
Measuring principle
Hydrostatic pressure
-
Characteristic
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Cable version with suspension clamp -
Supply voltage
4…20 mA HART
10,5…45 VDC (Non Ex):
Ex ia: 10,5…30 VDC
PROFIBUS PA:
9…32 VDC (Non Ex)
FOUNDATION Fieldbus:
9…32 VDC (Non Ex) -
Reference Accuracy
Standard 0.2%
Optional 0.1% -
Long term stability
0.05 % of URL/year
-
Process temperature
PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F -
Ambient temperature
-40°C…85°C
(-40°F…185°F) -
Measuring cell
100 mbar…10 bar
(1.5 psi…150 psi) -
Smallest calibratable span
10 mbar (1.45 psi)
-
Vacuum resistance
0 mbar abs.
-
Max. Turn down
100:1
-
Max. overpressure limit
40 bar (600 psi)
-
Process connection
Mounting clamp
-
Material process membrane
316L, AlloyC,
Gold-Rhodium
PE, FEP -
Material gasket
Viton, EPDM, Kalrez, none
-
Fill fluid
Inert oil,
Synthetic oil -
Material housing
316L, Die-cast aluminum
-
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1
NACE MR0175 -
Marine approvals
GL/ ABS/ LR/ BV/ DNV
-
Drinking water approvals
KTW/ NSF/ ACS
-
Specialities
Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions
Benefits
-
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
-
Modular concept for easy replacement of display or electronics
-
Seamless and independent system integration (HART/PA/FF)
-
Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
-
International usage thanks to a wide range of approvals
Endress+Hauser Hydrostatic Level Transmitter Other Available Models:
Deltapilot FMB51
Deltapilot FMB52
Deltapilot FMB53
Waterpilot FMX11